SUV correction for injection errors in FDG-PET examination

by: Kouichi Miyashita, Nobukazu Takahashi, Takashi Oka, Shinobu Asakawa, Jin Lee, Kazuya Shizukuishi, Tomio Inoue
Annals of Nuclear Medicine, Vol. 21, No. 10. (19 December 2007), pp. 607-613.


View FullText article


X Reviews [Write a review of this article]

There are no reviews of this article

X Find related articles from these CiteULike users

X Find related articles with these CiteULike tags

X Abstract

Abstract Objective  Many studies have documented the clinical usefulness of standardized uptake values (SUV) for diagnosis. However, in the event of injection error, accurate measurements cannot be obtained if the radioactivity of fluorodeoxyglucose (FDG) leakage is not subtracted from the administered dosage. Here, a correction formula for radioactivity estimation that takes into account the radioactivity of FDG leakage was derived on the basis of a phantom experiment. Furthermore, to determine whether SUV could be accurately calculated by the correction formula, we performed a volunteer study. Methods  Images were displayed by altering the conversion constant from 1.0, 0.1 to 0.01, and the range of correctable counts was verified on the basis of image inversion. To estimate the radioactivity of FDG leakage by imaging, the count of the leakage was measured, converted into a radioactivity concentration using a cross-calibration factor (CCF), and multiplied by volume, as measured by imaging. Three factors that markedly affect count, i.e., count rate performance, partial volume effect and crosstalk, were assessed in phantom studies in order to derive a correction formula. In addition, to clarify the accuracy of the correction formula, we attached to the right elbow. Results  With a conversion constant of 0.1, there was no image inversion at ≤1.565 MBq/ml. At concentrations below this, the average detection rate was 90%. This suggests that count rate performance can be corrected at ≤1.0 MBq/ml. Crosstalk investigations clarified that the effects of adjacent radioactivity concentrations on FDG leakage were not marked. On the basis of investigations on partial volume effect and count rate performance, the following formulas were derived: For leakages of ≥28 mm Leakage radioactivity (MBq) = positron emission tomography (PET) radioactivity (MBq) × 0.9. For leakages of ≥15 mm but <28 mm Leakage radioactivity (MBq) = PET radioactivity (MBq) × 0.9 × (0.0517 × leakage size (mm) − 0.4029). In a volunteer study with 10 MBq leakage, SUV recalculated using the formula achieved 99.97% correction, whereas with 100 MBq leakage, SUV achieved 67.5% resulting in poor correction. Conclusions  The present correction technique can accurately calculate SUV and could be useful for the clinical diagnosis of malignant tumors.


X BibTeX record

X RIS record



RIS BibTeX
CiteULike organises scholarly (or academic) papers or literature and provides bibliographic (which means it makes bibliographies) for universities and higher education establishments. It helps undergraduates and postgraduates. People studying for PhDs or in postdoctoral (postdoc) positions. The service is similar in scope to EndNote or RefWorks or any other reference manager like BibTeX, but it is a social bookmarking service for scientists and humanities researchers.